Akruti Elegance, Gavanpada, Mulund East

Calibration of Instruments

We offers a full range of both Lab based & Field based calibration services to our customers focused on the highly flammable environment. We have the largest team of fully trained Field Service Instrument Technicians focused exclusively on the industries related Oil & Gas Sector. We are providing a full range of Onsite Calibration Services & seeks to minimize any downtime associated with Annual Calibration requirements.

Silent Features

  • Highly Qualified Personnel.
  • Modern & Reliable Calibration Set Up.
  • Annual Agreements and Contracts for Calibration Service.
  • Very Competitive rates.
  • Quick and Professional Service.

Facilities Available

  • Calibration of Pressure Gauges & Pressure Transmitters.
  • Calibration of Temperature Gauges & Sensors.
  • Calibration of Safety Relief Valves.
  • Calibration of Gas Detector & Flame Detector.

Calibration of Pressure Gauges & Pressure Transmitters by Comparison Test Pump (Oil Operated) with Microprocessor Based Pressure Indicator

(NABL Accredited Calibration Certificate – as per ISO/IEC 17025:2005 Laboratory)

We are offering the services for Calibration of Pressure Gauges & Pressure Transmitters. Our offered services are highly effective and precisely designed, due to use of diligent professional engineers. Our Lab provides the confidence to our customers seek in identifying a one stop calibration service that will meet the unique requirements. These services are offered to our clients in compliance with latest industrial norms with full assurance of in time completion. Furthermore, we intend to providing these services at competitive market rates.

  • Range: 0 to 700 Bar
  • Type : Screw Pump
  • Accuracy : ± 0.05% F.S./ ± 0.025% F.S.
  • Pressure generation : Priming Pump for initial pressures & Screw RAM Pump for high Pressures
  • Medium : Oil

Calibration of Temperature Gauges & Sensors by Microprocessor Based Universal Temperature Calibrator

(NABL Accredited Calibration Certificate – as per ISO/IEC 17025:2005 Laboratory)

We are offering the services for Calibration of Temperature Gauges & Sensors. Our offered service are extensively used in various Industries for effective calibration of temperature gauges and sensors. Our offered services are highly effective and precisely designed, due to use of diligent professional engineers.

Advanced – Micro Controller based Technology, Switch Test Contact Measurement, Interchangeable Thermowell (Single / Multihole), RS-232 Interface & Calibration Software enable us to provide highly precise calibration services to our clients.

  • Range: 50°C to 650°C
  • Accuracy : ±0.6°C
  • Resolution :0.1°C
  • Stability : ±0.05°C
  • Temperature Readout :°C / °F Switch

Calibration of Safety Relief Valvesby Comparison Test Pump (Water Operated) with Microprocessor Based Pressure Indicator

(NABL Accredited Calibration Certificate – as per ISO/IEC 17025:2005 Laboratory)

With the Microprocessor Based Pressure Indicator, SICOM has the ability to test relief valves and identify those in need of adjustment or full service with no operational interruptions. Calibration of pressure relief valves are performed by highly trained executives.The result is a certifiable test allowing correctly performing valves to remain in service for longer periods, as well as the valves that do not meet the correct performance criteria by our experienced personnel so that they can be repaired or replaced.

  • Range: 0 to 700 Bar
  • Type : Screw Pump
  • Accuracy : ± 0.05% F.S./ ± 0.025% F.S.
  • Pressure generation : Priming Pump for initial pressures & Screw RAM Pump for high Pressure
  • Medium : Water

Calibration of Gas Detector

Gas detector is the only instrument which perform key role by avoiding injury & fatalities of peoples/workers working in toxic & gaseous areas.

The only way to know whether this instrument is capable of proper performance is to expose it to test gas. Exposing the instrument to known concentration test gas verifies that gas is properly able to reach and be detected by the sensors.

SICOM uses complete line of calibration gas mixture cylinders (filled in 3 Ltr. WC CS Cylinder) with 2.5% (50% LEL) Methane + Bal. Air that helps to check proper performance of Gas Detector. This method is very simple and takes only a few minutes to accomplish. It is not necessary to make a calibration adjustment unless the readings are found to be inaccurate. Gas detector is calibrated in accordance with the manufacturer’s recommendations & as per the requirments of clients. We offer full service and repair facilities at customer sites for fixed and portable Gas detection equipment.

Currently we have done calibration of 3000+ Gas Detectors. With the help of advanced technology & right tools, our well trained Instrumentation Engineers are enough capable to reduces downtime and maintenance cost of Gas Detectors.

Calibration of Flame Detector

Flame Detector is 2ndmost important safety device used in many companies/plants like Petroleum, Chemical, Oil & Gas etc. This device detects the UV/IR rays illuminated from Fire & shutdown the system to avoid major accidents & explosions.

Periodic calibration & maintenance of Flame Detector eliminates risk of failure during Fire. Periodic system testing and inspection by our qualified specialists can detect many such problems for that we takes up Annual Maintenance and Service contracts of all leading brands of Fire detection and suppression system irrespective of its make, model & type.

Currently we have done calibration of 3000+ Flame Detectors.